SPECIFICATIONS
|
|
|
Test method
|
Transmit voltage analogue signals
through a special interface.
|
|
Test Principle
|
Transmission analogue signals voltage to
digital signals and stored.
|
|
Test Range
|
INput signal voltage from 0 to 10V.
|
|
Data Pick Up
|
Can be set at 1,10,100,400,600,1000
point per second.
|
|
Time of data Pick up
|
Can be set at 1,2,5,10,20,30,60 minutes.
|
|
Set display screen
|
Can be set at 1,2,5,10,20,30,60 minutes.
|
|
Scroll display screen
|
Can be set into ½, ¼, ¾- scroll display screen.
|
|
Auto File Name
|
Automatically generated by test dates
and reserve four digit sequential code. for example:2001-1217-0001,that means in can analyze 9999 times in a single day |
|
Voltage
|
AC110V. Frequency:60HZ. Other are available for customer require
|
|
Computer require
|
ISA Communicate interface, CPU over P-III 700, RAM over 128MB,Win 98 Operation system, CD-ROM, HD 20GB. |
|

|
|
Special Function Statement
|
|
Friction value range
|
0.33 \ 0.66 \ 1.00 \ 2.00
|
|
Tension range
|
100cN
|
|
Static Test Method
|
10 second discharge , static charge
|
|
Static display Range
|
+/- 5, 15, 50, 500, 5000V
|
|
Friction angle
|
45, 90, 180 and any angle
|
|
|
Analysis Statistic Statement
|
|
|
data statistic
|
Damping test data and display BOX PLOT chart for process analysis
|
|
Dragging section statistics
|
Can read any test data dragged and selected confined by mouse.
|
|
Modification range
|
Can be set up simple modification range or manual modification range
|
|
|
FEATURES
|
|
l
|
Can analyze various dynamic-static Friction coefficient , Rewind, Tension, Static analysis.
|
|
l
|
Can be cooperated with various inspection instruments with DC outputs , such as temperature, humidity, rpm, wind speed, etc.
|
|
l
|
All the analyzed data will be calculated and displayed instantaneously, unlike the other test software, which have to test and save the data first and calculate and analyze the data later.
|
|
l
|
Can be set up simple modification range or manual modification range. (change tension、 Bar diagram, analysis time etc)
|
|
l
|
Can read any test data dragged and selected confined by mouse.
|
|
|